Schliesssystem
Schema
{Laptop,Handy,Tablet} <-> WRT <-> ethernet GPIO device <-> {Keymatic, Sprechanlage}
DING
Command Interface
The DING listens on *:2701/TCP for incoming connections. The protocol is ECMD with doorctl extensions.
mode set
doorctl mode set <mode>
sets the mode #Mode
Mode
The DING has a mode register for the inner door that is always set to one of the following values:
Mode | Default | LED value | Keymatic action when entering mode |
ERT effect |
---|---|---|---|---|
locked
|
X | --RRR--
|
lock door | nothing |
unlocked
|
OO-----
|
unlock door | nothing | |
unlocked+ert
|
-----GG
|
unlock door | retract safety catch |
Pinout
- relais 1: keymatic.close
- relais 2: keymatic.open
- relais 3: siedle.open
Connector pinout
These are the pinouts of the two flat cables coming from entryphone and keymatic.
Siedle entryphone
- Pin 1: door opener connector a
- Pin 2: door opener connector b
- Pin 3: ERT connector a
- Pin 4: ERT connector b
- Pin 5-10: not used
Keymatic
- Pin 1: Pushbutton lock/unlock (?)
- Pin 2: Pushbutton common
- Pin 3: Pushbutton lock/unlock (?)
- Pin 4: RI common
- Pin 5: RI dooropener
- Pin 6: RI lock/unlock (?)
- Pin 7: RI lock/unlock (?)
- Pin 8: unused
- Pin 9: RI power supply
- Pin 10: RI power supply
Todo
neuen Schliesszylinder installierenGPIO device installierenkeymatic verkabeln und an GPIO device anschliessensprechanlage an GPIO device anschliessen- auth-system
- netzwerkconfig
- GPIO-Device korrekt aufhaengen
- Gemeinsame Stromversorgung
- Fritzbox (?)
- brickme (?)
- Keymatic (12V)
- DING (5V)
- Telefon (?)
- Tuermagnet
- Temperatursensor